U225XTHE RECORD REMAINSSEARCH
← RETURN TO INDEX
RECORD LOCATED / 2026.09.01

Scan-to-CAD deviation and QC workflow

A deviation map is meaningful only when alignment, units and acceptance limits are defined.

CAD-029REV A
AI narration using Robert's voice. Scan-to-CAD deviation and QC workflow / short introduction.
Open notebook ↗
A CLOSER LOOK

Missing coverage is not a passing color

Missing coverage is not a passing color. Conceptual deviation-report legend; no artificial scan results are plotted.OPEN FULL SIZE ↗
Conceptual deviation-report legend; no artificial scan results are plotted.Explanatory drawing based on this record
Define
Alignment, units and acceptance limits
Separate
Measured deviation / missing coverage
Report
Method and limitations
CLASSIFICATIONCAD
STATUSStarting Point
MATERIALCAD / AUTOMATION
DISPOSITIONPUBLIC / STARTING POINT
VIEW FILE ↗

TECHNICAL NOTES///

A deviation map is meaningful only when alignment, units and acceptance limits are defined.

PUBLIC KNOWLEDGE VIEWCAD / Scanning / Automation / how-to

GOALRun the first test described in this guide and record the result for scan-to-cad deviation and qc workflow.

EQUIPMENT

  • Scanner / mesh workflow
  • Representative test model
  • Measurement or inspection method

STEPS

  • Record the nominal CAD revision, scan units, acquisition conditions and required datums.
  • Align to inspection datums for a datum-based check; use best-fit only when that is the intended question and label it clearly.
  • Set a fixed color scale and report missing coverage separately from measured deviations.
  • Measure critical sections and independent reference dimensions, then save a report with alignment method and uncertainty limitations.

TROUBLESHOOTING

  • Best-fit can hide a shifted hole or a datum error. A green color map may simply use a broad tolerance band. Missing scan data is not a passing measurement.

THINGS TO WATCH FOR

Best-fit can hide a shifted hole or a datum error. A green color map may simply use a broad tolerance band. Missing scan data is not a passing measurement.

RESULTAnother reviewer can reproduce the alignment and understand where measurements are valid.

DEVELOPMENT HISTORY///

2026.09.01Rev A

Imported as an independent manifest record; public copy keeps uncertainty visible.

SPECIFICATION///

Tool pathScanner / mesh workflow
DeliverableHOW-TO
ValidationRepresentative model / known dimension
StatusStarting Point

RELEASED MATERIAL///

cad-029-public-summary.txtPUBLIC SUMMARY / RECOVERED NOTES
WHERE THIS STANDS

Another reviewer can reproduce the alignment and understand where measurements are valid.

The record keeps what is known at this revision. Unfinished tests stay unfinished here.
RECORD CAD-029DISPOSITION / PUBLIC / STARTING POINTBUILD 0.4.17