U225XTHE RECORD REMAINSSEARCH
← RETURN TO INDEX
RECORD LOCATED / 2026.09.01

Hexagon scanner/probe and DezignWorks workflow

Use probing for discrete functional references and scanning for surface coverage within the supported arm/software combination.

CAD-027REV A
AI narration using Robert's voice. Hexagon scanner/probe and DezignWorks workflow / short introduction.
Open notebook ↗
A CLOSER LOOK

Probe datums, scan surfaces

Probe datums, scan surfaces. Conceptual discrete probing and dense scanning referenced to the same datum frame.OPEN FULL SIZE ↗
Conceptual discrete probing and dense scanning referenced to the same datum frame.Explanatory drawing based on this record
Probe
Planes, bores and key points
Scan
Complex surface coverage
Reference
Functional datums
CLASSIFICATIONCAD
STATUSStarting Point
MATERIALCAD / AUTOMATION
DISPOSITIONPUBLIC / STARTING POINT
VIEW FILE ↗

TECHNICAL NOTES///

Use probing for discrete functional references and scanning for surface coverage within the supported arm/software combination.

PUBLIC KNOWLEDGE VIEWCAD / Scanning / Automation / how-to

GOALRun the first test described in this guide and record the result for hexagon scanner/probe and dezignworks workflow.

EQUIPMENT

  • Scanner / mesh workflow
  • Representative test model
  • Measurement or inspection method

STEPS

  • Confirm the arm/probe model, calibration status and supported DezignWorks integration. Secure the part and arm setup.
  • Establish the part coordinate system from functional datums rather than arbitrary scan orientation.
  • Probe planes, bores and key points as appropriate; scan complex surfaces where dense data adds value.
  • Build and constrain the CAD features from those references, then verify critical dimensions independently and archive raw data.

TROUBLESHOOTING

  • A moved arm or fixture can invalidate the established alignment. Probe compensation and calibration matter. Do not claim a specific Hexagon model or certified uncertainty without its records.

THINGS TO WATCH FOR

A moved arm or fixture can invalidate the established alignment. Probe compensation and calibration matter. Do not claim a specific Hexagon model or certified uncertainty without its records.

RESULTThe CAD model uses documented datums and checked critical dimensions, with raw acquisition data retained.

DEVELOPMENT HISTORY///

2026.09.01Rev A

Imported as an independent manifest record; public copy keeps uncertainty visible.

SPECIFICATION///

Tool pathScanner / mesh workflow
DeliverableHOW-TO
ValidationRepresentative model / known dimension
StatusStarting Point

RELEASED MATERIAL///

cad-027-public-summary.txtPUBLIC SUMMARY / RECOVERED NOTES
WHERE THIS STANDS

The CAD model uses documented datums and checked critical dimensions, with raw acquisition data retained.

The record keeps what is known at this revision. Unfinished tests stay unfinished here.
RECORD CAD-027DISPOSITION / PUBLIC / STARTING POINTBUILD 0.4.17