Copy model/drawing and replace all references

Create an independent copy without leaving drawings or assemblies linked to the old model unintentionally. Work on a copy first. Record application version, units and active document/configuration. Names below identify the catalogued workflow; they do not claim a particular button layout or verified implementation.

CAD-061REV A
AI narration using Robert's voice. Copy model/drawing and replace all references / short introduction.
Open notebook ↗
A CLOSER LOOK

Copy the reference graph, not just filenames

Copy the reference graph, not just filenames. Conceptual old-to-new dependency map with explicit shared parts.OPEN FULL SIZE ↗
Conceptual old-to-new dependency map with explicit shared parts.Explanatory drawing based on this record
Map
Explicit old to new
Include
Required dependent files
Test
Originals unavailable in a test location
CLASSIFICATIONCAD
STATUSRecovered/Partial
MATERIALCAD / AUTOMATION
DISPOSITIONPUBLIC / RECOVERED/PARTIAL
VIEW FILE ↗

TECHNICAL NOTES///

Create an independent copy without leaving drawings or assemblies linked to the old model unintentionally.

PUBLIC KNOWLEDGE VIEWCAD / Scanning / Automation / how-to

GOALRun the first test described in this guide and record the result for copy model/drawing and replace all references.

PREPARATION / NOTES

Work on a copy first. Record application version, units and active document/configuration. Names below identify the catalogued workflow; they do not claim a particular button layout or verified implementation.

EQUIPMENT

  • CAD / automation tool
  • Representative test model
  • Measurement or inspection method

STEPS

  • Build a dependency list and choose destination filenames with collision handling.
  • Use the application’s supported copy/reference workflow and include all required dependent files.
  • Replace references using an explicit old-to-new map, preserving configurations and relative relationships.
  • Open the copied top-level model and drawing with the originals unavailable in a test location, then rebuild and inspect references.

TROUBLESHOOTING

  • Renaming a file in Explorer is not a complete reference update. Shared purchased components may intentionally remain shared; define that policy first.

THINGS TO WATCH FOR

Renaming a file in Explorer is not a complete reference update. Shared purchased components may intentionally remain shared; define that policy first.

RESULTThe copied project resolves only to the intended new or explicitly shared files.

DEVELOPMENT HISTORY///

2026.09.01Rev A

Imported as an independent manifest record; public copy keeps uncertainty visible.

SPECIFICATION///

Tool pathCAD / automation tool
DeliverableHOW-TO
ValidationRepresentative model / known dimension
StatusRecovered/Partial

RELEASED MATERIAL///

cad-061-public-summary.txtPUBLIC SUMMARY / RECOVERED NOTES
WHERE THIS STANDS

The copied project resolves only to the intended new or explicitly shared files.

The record keeps what is known at this revision. Unfinished tests stay unfinished here.
RECORD CAD-061DISPOSITION / PUBLIC / RECOVERED/PARTIALBUILD 0.4.17